φ45 5000:1 800A Split core current transformer

Structural Parameters


       Front View Lateral View

                                                    “*” Same polarity


Product Description

Details

Product characteristics and application

 

Rated input current

800A

Accuracy class

0.5

Rated output current

160mA

Installation

Split core type

Turns ratio

5000:1

Operating

temperature

-25~+75

Operating current

0~960A(10Ω)

Relative humidity

≤95

Case material

Nylon

Operating

frequency

50HZ/60HZ

 

(1) Dielectric strengthpower frequency between primary winding and secondary winding 2.5KV/min, no breakdown flash-over phenomenonleakage current1mA;

(2) Insulation resistorBetween primary winding and secondary winding ≥1000MΩ/500Vdc


 

Error Range

 

Input current

5

20

100

120

Ratio error (±%)

±0.75

±0.5

±0.5

±0.5

Phase error (′)

≤30

≤20

≤20

≤20

 

Reliability test

 

No.

Items

contents

condition

Application standard

1

High temperature

storage

Durability test, long time high temperature

storage.

85  48hours

Corporate standard

2

Low temperature

storage

Durability test, long time low temperature

storage.

-40  48 hours

Corporate standard

3

High temperature

operation

Durability test, long time in the state of high

temperature power.

75  16 hours

 

Corporate standard

4

Low temperature

operation

Durability test, long time in the state of low

temperature power.

-2516 hours

Corporate standard

5

High temperature/high humidity storage

Durability test, high temperature and high humidity storage for a long time.

60  , 90 %RH 48 hours

Corporate standard

6

High temperature/high humidity operation

Durability test, long time in high temperature and high humidity power on state.

40 , 90 %RH 16 hours

Corporate standard

 

7

 

Cold and hot cycle shock

Durability test in electrified and cold and hot cycle condition. 25 5min. 1 Cycle 70 30min

-20 30min

 

-20°C / 70°C 10 Cycle

 

Corporate standard

Mechanical test

 

 

8

 

 

Vibration test

 

Durability testing, transportation and use in the state of vibration.

Frequency105510Hz amplitude1.5mm Cycle1 Log/min timeX.Y.Direction 0.5 hour

each

 

 

Corporate standard

 

Label Content

 