Φ8.8mm Current transformer Flying Wires 1000:1 60A

production description

ZMCT124H  Current transformer

Small sizehigh accuracyfood consistencyFor accurate current and power measurement

 

Structural parameter:

                  Front view                                   Bottom view

The main technical parameters

Model

ZMCT124H

input current

0~60A(10Ω)

Rated output current

5mA at input 5A

Turns ratio

1000:1

phase angle errorRated input

30(input 5A, sampling resistor 10Ω)

Accuracy class

0.2

linearity

0.2%(5%dot~120dot of 5A)

Permissible error

-0.2% ≤ f +0.2% (input 5A, sampling resistor 10Ω)

Isolation voltage

4500V

Application

measurement  or  protection

Encapsulation

Epoxy

Installation

PCB mounting (Pin length>3mm)

operating temperature

-40~+85

Direction for use:

  

                        Figure                        Figure

1. The typical usage of the product is for the active output (Figure ). R is a sampling resistor. C & R is for phase compensation.

2. The product can be directly through the resistance sampling, easy to use (Figure).

 